COVID-19 Swab Booths (Brau LAB Shield Box SBA-100)

Biosafety Cabinet

Sort by new items      Sort A to Z

COVID-19 Swab Booths (Brau LAB Shield Box SBA-100)


COVID-19 Numune Alma Kabini (Brau LAB Shield Box SBA-100)

COVID-19 Numune Alma Kabini (Brau LAB Shield Box SBA-100)
Dimensions: 100x62x210h


The sampling booth is used to take nasopharyngeal swabs from patients with or possibly contagious diseases, especially Covid-19. While the patients with the possibility of Covid + are standing outside of the sampling cabinet, the healthcare personnel who will take samples are standing inside. It can be used with disposable gloves or fixed gloves. The sample drawer is used to safely transfer the culture stick to the other side.

What is Biological Safety Cabinet BSC (Biosafety Cabinet)?

Devices that provide the environment needed when biological pollutants are released and / or sensitive work away from the effects of biological pollutants are called biological safety cabinets or biosafety cabinets. Contaminating particles often cause respiratory damage. Biological agents, which can hang in the air with the inhaled air, can spread to the whole body by entering the lungs and from there into the bloodstream. In order to identify and prevent hazards that may occur before or after working in the laboratory, or to minimize the likelihood of occurrence, safe working conditions for human health should be provided based on scientific methods. Sterile Cabinet is a device that enables all kinds of work done with biological agents (sowing, analysis, experiment etc.) in laboratory environments safely. BRAU GROUP designs and manufactures biosafety cabinets in various models for a better laboratory working environment.

Biological Safety Cabinet Models

Biosafety cabinets are basically produced in 4 standards.

  • Clean Bench
  • Class I
  • Class II
  • Class III
  • biosafety cabinet

    Circulation fan motors, air inlets, outlets, lighting, filters etc. are located in the upper part. In the working area, there is a glass cover, gas fittings and worktop that vary depending on the model. In the control panels section, depending on the model, generally, electrical sockets, blower, sterilizer and lighting control switches etc. digital indicators are available.

    How To Use Biological Safety Cabinet?

    The biological safety cabinet should be placed indoors where the traffic is the least, away from air conditioning systems, doors and windows. The biosafety cabinet should be made of water, moisture and chemical resistant material. The air extraction system in the biosafety cabinet must be capable of providing continuous airflow and can operate 24 hours a day. Electrical installations and equipment and mechanical installations and equipment must be isolated from each other. Electrical outlets and switches must be protected. Burners and heaters that can generate excessive heat can damage Hepa filters, so their use in the biosafety cabinet should be taken into consideration and bunsen burners should not be opened too close to the filters. Preventing materials should not be in front of the suction grilles. Air suction and outlet grilles should be always open. Security measures should be taken before working in the biosafety cabinet.

    The cause of human errors is often lack of information and carelessness. Despite all the precautions taken, an accident that may occur in the laboratory environment should be taken into consideration and a first aid team should be available in the institution.

    biyo güvenlik kabini
    steril kabin
    steril-kabin-panel
    steril kabin

    Microbiology, biochemistry, cytotoxic drug preparation etc. Biological safet cabinets should be used when working in areas or when working with carcinogenic substances. Biosafety cabinets must be absolutely connected to a ground-protected electrical installation. The ventilation fan should be activated before the safety cabinet front sash is opened. According to the model, work should be started after the sterilization of the air circulation inside is completed for a certain period of time. This time varies by model, but it should be at least five minutes. When the microbiological safety cabinets are not used, the front sash must be closed. During operation, front sash should be lowered to the lowest possible level. In this way, the connection of the indoor environment with the outside will be minimized. In some studies, users may need to wear extra masks and protective lab glasses.

    